ExoAir® 130 Fluid-Applied Synthetic Air and Vapor Barrier Membrane is a monolithic, elastomeric membrane designed to seal exterior above-grade wall assemblies and mitigate air infiltration/exfiltration, vapor transmission and water penetration. It is available in a single grade that can be roller or spray applied using the appropriate spraying equipment.
ExoAir 120 and ExoAir 220 can handle intermittent temperatures of up to 158˚F (70°C). ExoAir 130 and ExoAir 230 can handle intermittent temperatures of up to 240˚F (115°C).
Primer is not required prior to application of ExoAir 120/220. ExoAir Primer is also generally not required when applying ExoAir 230 unless you are applying it onto metal or transitioning it onto the exposed face of ExoAir 110. ExoAir Primer is required prior to the application of ExoAir 110.
The cure-through of the ExoAir fluids ranges between 24-48 hours when evaluated at temperatures between 40°F - 90°F (5°C - 32°C) and relative humidity between 50-75%. When co-sprayed with calcium chloride solution, ExoAir 120 will require approximately 30 minutes to become tack-free. but 24 hours to achieve full cure.
ExoAir 120: 60 wet mils to achieve 40 dry mils (25 sq ft/gallon)
ExoAir 220: 70 wet mils to achieve 40 dry mils (23 sq ft/gallon)
ExoAir 230: 70 wet mils to achieve 35 dry mils (23 sq ft/gallon)
Note: There are 1000 mils in 1” (25.4mm), so 40 dry mils = 0.04” (1mm).
Tremco recommends that fluid-applied ExoAir membranes be applied to surfaces and ambient conditions above 40˚F (5°C). ExoAir fluids should not be applied to surfaces or when ambient conditions are expected to fall and remain below 40˚F (5°C) during the 24 hours immediately following installation.
Yes, all the ExoAir membranes have passed the ASTM tests for nail sealability. The typical nail sealability tests include a smooth roofing nail. Tremco has also tested for nail sealability with a variety of screws and other fasteners. Please refer to the Technical Bulletin for nail sealability.
Construction gaps in exterior substrates less than 1/16” (1.6mm) do not require detailing prior to the application of ExoAir fluid-applied membranes. Construction gaps greater than 1/16” (1.6mm) need to be filled with Dymonic 100, Tremflex 834, or other approved product. Allow sufficient time for detail work to cure prior to application of ExoAir fluid-applied membranes.
During installation, a standard wet mil thickness gauge is used every 50-100 sq ft to verify thickness. It can also be approximated by staging material. For example, ExoAir 120 is applied at 25 sq ft/gallon and if a 5-gallon pail is being used, approximately 125 sq ft could be installed with one pail of product. By applying the contents of one pail of ExoAir 120 to 125 sq ft of wall area, you attain an average of 60 wet mils thickness over that area.
Allow the ExoAir fluids to cure for a minimum of 2-4 days prior to performing adhesion testing. If during this cure period the fluids are exposed to temperatures below 40˚F (5°C), you may have to wait longer in order to achieve a full through cure prior to perform adhesion testing.
ExoAir fluid-applied membranes should be protected from UV exposure and possible site damage from other trades as soon as possible following application. Any prolonged exposure requires an inspection of the membrane in order to evaluate continuity and repair any damage. The following UV exposure periods are acceptable provided the membrane has not been compromised: ExoAir 120 – 30 days, ExoAir 220 – 6 months, ExoAir 230 and 130– 12 months.
12 months.